Summary: SstFileWriter ignore Options::bottommost_compression, update it to use bottommost_compression if available
Test Plan:
make check -j64
verified used compression using ./sst_dump
Reviewers: sdong
Reviewed By: sdong
Subscribers: andrewkr, dhruba, yoshinorim
Differential Revision: https://reviews.facebook.net/D59841
Summary:
This adds a new metablock containing a shared dictionary that is used
to compress all data blocks in the SST file. The size of the shared dictionary
is configurable in CompressionOptions and defaults to 0. It's currently only
used for zlib/lz4/lz4hc, but the block will be stored in the SST regardless of
the compression type if the user chooses a nonzero dictionary size.
During compaction, computes the dictionary by randomly sampling the first
output file in each subcompaction. It pre-computes the intervals to sample
by assuming the output file will have the maximum allowable length. In case
the file is smaller, some of the pre-computed sampling intervals can be beyond
end-of-file, in which case we skip over those samples and the dictionary will
be a bit smaller. After the dictionary is generated using the first file in a
subcompaction, it is loaded into the compression library before writing each
block in each subsequent file of that subcompaction.
On the read path, gets the dictionary from the metablock, if it exists. Then,
loads that dictionary into the compression library before reading each block.
Test Plan: new unit test
Reviewers: yhchiang, IslamAbdelRahman, cyan, sdong
Reviewed By: sdong
Subscribers: andrewkr, yoshinorim, kradhakrishnan, dhruba, leveldb
Differential Revision: https://reviews.facebook.net/D52287
Summary:
Added the column family name to the properties block. This property
is omitted only if the property is unavailable, such as when RepairDB()
writes SST files.
In a next diff, I will change RepairDB to use this new property for
deciding to which column family an existing SST file belongs. If this
property is missing, it will add it to the "unknown" column family (same
as its existing behavior).
Test Plan:
New unit test:
$ ./db_table_properties_test --gtest_filter=DBTablePropertiesTest.GetColumnFamilyNameProperty
Reviewers: IslamAbdelRahman, yhchiang, sdong
Reviewed By: sdong
Subscribers: andrewkr, dhruba, leveldb
Differential Revision: https://reviews.facebook.net/D55605
Summary:
SstFileWriter may create an sst file with no entries
Right now this will fail when being ingested using DB::AddFile() saying that the keys are corrupted
Test Plan: make check
Reviewers: yhchiang, rven, anthony, sdong
Reviewed By: sdong
Subscribers: dhruba
Differential Revision: https://reviews.facebook.net/D52815
Summary: Pass column family ID through TablePropertiesCollectorFactory::CreateTablePropertiesCollector() so that users can identify which column family this file is for and handle it differently.
Test Plan: Add unit test scenarios in tests related to table properties collectors to verify the information passed in is correct.
Reviewers: rven, yhchiang, anthony, kradhakrishnan, igor, IslamAbdelRahman
Reviewed By: IslamAbdelRahman
Subscribers: yoshinorim, leveldb, dhruba
Differential Revision: https://reviews.facebook.net/D48411
Summary:
This is an initial version of bulk load feature
This diff allow us to create sst files, and then bulk load them later, right now the restrictions for loading an sst file are
(1) Memtables are empty
(2) Added sst files have sequence number = 0, and existing values in database have sequence number = 0
(3) Added sst files values are not overlapping
Test Plan: unit testing
Reviewers: igor, ott, sdong
Reviewed By: sdong
Subscribers: leveldb, ott, dhruba
Differential Revision: https://reviews.facebook.net/D39081