Prevent manual flush hanging in read-only mode (#4615)
Summary: The logic to wait for stall conditions to clear before beginning a manual flush didn't take into account whether the DB was in read-only mode. In read-only mode the stall conditions would never clear since no background work is happening, so the wait would be never-ending. It's probably better to return an error to the user. Pull Request resolved: https://github.com/facebook/rocksdb/pull/4615 Differential Revision: D12888008 Pulled By: ajkr fbshipit-source-id: 1c474b42a7ac38d9fd0d0e2340ff1d53e684d83cmain